Laserfiche WebLink
M1 :eAw tllall JIIVWIII Io <br /> scale is ze and location o, .::.: new construction and all emsting structures on the <br /> site, distances from lot lines, the established street grades if they exist (verified by <br /> the town or city) and proposed finished grades. In the case of demolition, the site <br /> plan shall show all construction to be demolished and the location and size of all <br /> existing structures and construction that are to remain on the site or plot. The site <br /> plan shall not be changed except as specified in Sections 113.8 and 115.3. <br /> 113.7 Engineering details: The building official may require adequate details of <br /> structural, mechanical and electrical work, including computations, stress diagrams <br /> and other essential technical data, prepared by a registered professional engineer <br /> qualified by experience in the specific field of construction, to be filed. All such <br /> plans and computations shall bear the Massachusetts seal of registration and <br /> signature of the qualified registered professional engineer or architect. <br /> 113.8 Independent1 structural engineering reviews As a condition for the <br /> issuance of a bu►Idin erm►t the structural design of the following described <br /> structures shall be reviewed b an Inde endent structural en ineer to verifythat the <br /> design of the primary structure is conceptuallycorrect and that there are no major <br /> errors in the des► - . <br /> ka <br /> 1-16 780 CMR - Fifth Edition 6/5M (EtTMwe 6/19M) <br />—"�Y—�l:'"1J_LL114'[IiPJTI111.11—a1{i"1lvG-'IJI "J LVCI\.Tp{""IfIVI\i "11T-fl�ilrlll VV \. 411. IV tY GJC'—"------ - <br /> floor. including stones below grade <br /> 2. Buildings which enclose a total volume of 400,000 cubic feet including <br /> stones below grade. The volume shall be measured using the outside <br /> dimensions of the building. <br /> 3. Structures in Use Group A or structures which are partially in Use <br /> Group A. which will be used for public assembly of-300 or more persons <br /> 4. Structures of unusual complexity or design shall be determined by the <br /> BBRS. A building official may aQply to the BBRS for such a <br /> determination on a specific structure <br /> Exemption: Temporary structures erected for a period of 180 days or less <br /> 113.8.1 Requirements for the review: The independent structural en ineeriniz <br /> review shall be in accordance with the requirements of Appendix I <br /> 113.9 Amendments to application: Subject to the limitations of Section 113.10, <br /> amendments or revisions to a plan or other records accompanying the same may not <br /> be made until the proposed changes have been filed with and approved by the <br /> building official; and such approved amendments shall be deemed part of the <br /> original application and shall be filed therewith. <br />