My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1981-1982-TOWN MEETING RECORDS
TownOfMashpee
>
Town Clerk
>
Minutes
>
TOWN MEETING
>
TOWN MEETING CORRESPONDENCE
>
1980-1989
>
1982
>
1981-1982-TOWN MEETING RECORDS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2019 2:41:56 PM
Creation date
11/17/2016 3:35:02 PM
Metadata
Fields
Template:
Mashpee_Meeting Documents
Board
TOWN MEETING
Meeting Document Type
Minutes
Meeting Date
12/31/1982
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Via.,, <br /> ARTICLE i <br /> 35 To see if the Town will vote to amend the Town By- haws <br /> by adding the following to Chapter 4p Article 4.6, Section 4.6.6: � <br /> Any new structure containing more than one dwelling unit to be built <br /> in the Town of Mashpee, including but not limited to structures known .+ <br /> as condominiums, shall have installed an alarm system so prescribed <br /> by the Fire Chief as follows: <br /> Smoke detectors shall be installed on each level including the1,„' <br /> basement of each unit within the structure as prescribed by the <br /> Massachusetts State BuildingCode.. These smoke detectors shall , MI6 <br /> be local to the unit and wired on an essential circuit within the y , <br /> unit, such as the kitchen circuit. <br /> There shall be a rate of rise/fixed temperature heat <br /> detector <br /> installed on each level including the basement of each unit <br /> within the structure and a prescribed number of heat detectors <br /> in each attic space over each unit depending on the size of the <br /> attic. There shall be a fixed temperature heat detector in the <br /> room or space which houses the heatin <br /> structure. g plant for each unit or <br /> These heat detectors shall be part of a complete closed alarm,. <br /> system, local to the entire building or structure, therefor <br /> sounding around and throughout the entire building or structure. ;,,Ni 'f <br /> This system will be a low voltage system with a sixty- hour back- <br /> up. The AC power connection shall connect ahead of the main switch 3i <br /> with a locking device and key. The wiring for energy fire alarm <br /> wire rated at 106 centigrade. <br /> If the layout of a particular structure calls for common hallways epi°a ' <br /> thereshall be smokedetectors ineach hallway which are wired to the h'+ ' <br /> low voltage alarm system, the number and location to be determined <br /> by $he Fire Chief.These hallway smoke detectors shall be equippdd <br /> with at least; a ni:n69) second delay capacitor and screen. Also if <br /> pull station at either t�> <br /> common hallways exist there shall be a ' <br /> er end <br /> of the hallway located as recommended by the Massachusetts State <br /> Building Code and ,a zone panel box in each common hallway. The <br /> number of zones and location of box shall be negotiable. <br /> i <br /> Within this low voltage alarm system in each building or structure <br /> there shall be installed exterior audible bells or horn and an It <br /> exterior rotating beacon light which shall be located as prescribed -, <br /> by the Fire Chief and which will be activated by the activation of <br /> any warning device within this closed system. These bells or horns + . <br /> shall also be installed in the common hallways, where they exist in <br /> any given building or structure. These bells or horns must be loud <br /> enough to be heard in any room in any unit within any given build- <br /> ing structure, q, <br /> f <br /> AtO <br />
The URL can be used to link to this page
Your browser does not support the video tag.