Laserfiche WebLink
4 <br /> 2e The grater supply line or well is not shown on the plans egulation *% <br /> e At least 2 deep observation holes should be shown on the plan in the <br /> proposed leach areas* Regulation 3*39 It is also recommended that <br /> the groundwater elevation be monitored over a full moon tidal cycle. <br /> A section of perforated PVC pipe with the mean seas level elevation <br /> marred by a registered land surveyor is recon w ded for this purposes <br /> 49 portion of the proposed leach facility is shorn under the.paces <br /> area and would therefore be subject to vehicular traffic. The <br /> trenches gust therefore be shown to be capable of withstanding HmP2 <br /> wheel loads. dation 14.34* <br /> It is recommended that elevatians shown on the plan be tied into an <br /> elevation referee marker as shown on the Flood insurance Rate Map* <br /> The plan should mote that a Registered Professional Engineer will <br /> certify the entire installation of the facility, <br /> The U - Probable High Ground#wa►ter levels on Cape Cod should be <br /> used to calculate any adjustment in the ground water ,level, <br /> S. It is also recommended that the appropriate man high water line be <br /> confimed <br /> The above cents refer only to Title v concerns. Obviously, this project <br /> ill require approval from the Mashpoe Conservation Commission,* <br /> Should you -desire any further assistance from our Agency,, please do not <br /> hesitate to contact me. <br /> t . <br /> Suer ly yours <br /> Ste on R& Hal <br /> Casty Health Officer <br /> SHaa <br />