Laserfiche WebLink
i r ' <br /> • <br /> off., <br /> Town of Mashpee <br /> 16 Great Neck Road North <br /> .. Mashee, Massachusetts 02649 <br /> BOARD of HEALTH PUBLIC SESSION <br /> Minutes of the Meeting of January '11, 2012 <br /> Board Members Present: Also Present; <br /> Lucy Burton, Chairman Glen.Harrington, Health Agent <br /> Kalliope Egf ,ff, Co-Chairman <br /> Burton Kaplan, Clerk <br /> Chairman Luer Burton called the meeting to order at 7:00 PM. <br /> APPOINTMENTS <br /> 7:15 PIIS - John Sla in y— Request t for Tale V Variances Bayview Road. <br /> Glen Harrington commented that the variances requested are due to the size of the lot. The proposed <br /> SAS will be 77' from the wetlands, and the Board has required a denite system to mitigate that <br /> variance. A Hoot System is proposed, and an ultra-violet light disinfection unit has been added for <br /> extra measure. Typically, the UV light is required if the SAS is less than 75' to the wetlands. The <br /> d rite is typical mitigation for the wetland variance. The Title V variances do not reed DEP approval. <br /> DEP has stated that setback variances will only need DEP review. <br /> *John Slavinsky of Cape and Islands Engineering introduced himself to the Board. <br /> 1r. Slavinsky is requesting setback variances: 1 ' from the street line, 2 ' from the foundation of the <br /> house, and a variance to the local regulation requiring greater than 100' setback. He is proposing the <br /> Hoot System with the UV light unit. <br /> David Holden and Marcia Holden abutters to the property introduced themselves to the Board. Mr. <br /> Holden is concerned with the variance to the wetlands. Burton Kaplan and Glen Harrington' explained <br /> to Mr. Holden that the state only requires 50' to the wetlands, whereas Mashpee requires 100'. The <br /> Hoot System and the UV light unit will also add protection to the wetlands. <br /> Ripley Crowell of 54 Bayview introduced himself to the Board and asked if there was a backup <br /> generator. Mr. Slavinky says that a backup generator is not in the plan. <br /> 1r. Holden closed with comments that everyone should understand the Hoot System and read the <br /> operation manual. <br /> Burton Caplan made a notion to approve the 5 variances and to include the installation of the Hoot <br /> Denitrification System along with an ultraviolet treatment system with testing for two years at 68 <br /> Bayview Road. Kalli pe Egloff seconded the motion. The motion was unanimously approved. <br /> 1 <br />