Laserfiche WebLink
EnviroScienceTechnology <br /> Because we all live down stream......... <br /> EST's Grease Trap Remedy and EST's Septic Remedy application test results of use at a famous, historic New England Inn, dating to the <br /> 1700s, on Cape Cod,Massachusetts <br /> The Inn has 53 rooms/suites, spa,pub, large commercial kitchen and restaurant with 3 dining rooms and banquet facilities; using approximately 1.5 million <br /> gallons of water per month. The Septic Remedy was applied to each drain throughout the Inn and Restaurant to cleanse the plumbing structure, and"shock"the <br /> septic tank, as well as into each of 12 portals in the leach fields to begin the cleaning/balancing process. The Grease Trap Remedy was applied directly into <br /> the two, in series,grease traps, as well as into the distribution pump portal,to begin the remedial process.Upon completion of the 3 week initial application, <br /> metering pumps were installed to feed the two Nature's Whey products into the respective systems. Samples are taken directly to Envirotech Laboratories MA <br /> CERT.NO.M-MA 063)in Sandwich,MA for analysis;here are results by sample dates(red shows reductions): <br /> PARAMETERS 1/11/06 2/17/06 change 3/23/06 4/27/06 6/12/06 7/28/06 10/17/06 12/22/06 change test method 's <br /> YTD <br /> Kjeldhal N(TKN) 42.5 31.9 <25% 37 40.3 31 3.3 29.7 30.8 <27.6% 351.3 <br /> Ammonia 25.5 24.1 <6% -- 28.8 26.3 30.2 30.2 24.8 <.0 % 350.2 <br /> t <br /> Nitrate BRL BRL -- BRL BRL BRL BRL 2.76 BRL --- 300.0 <br /> Nitrite N BRL BRL -- BRL BRL BRL BRL BRL BRL --- 300.0 BEFORE -January 2006 <br /> Total Nitrogen 415 31.9 <25% 37 40.3 31 3.3 32.5 .8 <27.6% calc. `_ <br /> ,a <br /> Oil&Grease 37.0 8.8 <76% 3.2 3.4 6.6 5 11 8.8 <76% 1664 <br /> Surfactants <.02 BRL -- .03 .01 .15 .13 <0.1 .08 >300% 5540C . <br /> Total Phosphates 11.7 10.8 <8% 11.9 12.3 7.3 6.67 1.29 6.87 <41.3% 4500-P <br /> E-coli 73k 280k <384% 27k --- 140k 20k 40k 7.2K <90.2% 9213 D <br /> measurements in parts per million,measured at end of leach field <br /> AFTER-May 2006 <br /> A competitor's bacterial product had been in use for 8 years,yet the grease trap was being pumped every 4 to 6 weeks,and bio-filters between the grease traps <br /> and septic tank, and the septic tank and leech fields were regularly clogged.After 60 days use of Nature's Whey, grease solids had been reduced to clear liquid, <br /> and bio-filter cleaning time and pumping requirements have been minimized. Maintenance dosages were begun on 5/l/06 <br /> Sampling will continue at 5 to 6 week intervals to demonstrate how increases and decreases in various parameters may fluctuate in a general downward trend. <br />