My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5/2/2011 SCHOOL COMMITTEE Minutes
>
5/2/2011 SCHOOL COMMITTEE Minutes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2018 5:03:29 PM
Creation date
4/20/2018 3:15:19 PM
Metadata
Fields
Template:
Mashpee_Meeting Documents
Board
SCHOOL COMMITTEE
Meeting Document Type
Minutes
Meeting Date
05/02/2011
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Y <br /> status. Inadequate ventilation and/or elevated temperatures are major causes of complaints such <br /> as respiratory, eye, nose and throat irritation, lethargy and headaches. For more information <br /> concerning carbon dioxide, consult Appendix A. <br /> Indoor temperature measurements ranged from' 68'F to 76° F, which were within or close <br /> to the tower end of the MDPH recommended comfort range in areas surveyed the day of the <br /> assessment(Table 1). The MDPH recommends that indoor air temperatures be maintained in a <br /> range of 7 ° F to 7 ° F in order to provide for the comfort of building occupants. In many cases <br /> concerning indoor air quality, fluctuations of temperature in occupied spaces are typically <br /> experienced, even in a building with an adequate fresh air suppler. <br /> Relative humidity in the building ranged from 26 to 64 percent. The MDPH recommends <br /> a comfort range of 40 to 60 percent for indoor air relative humidity. Relative humidity <br /> measurements were within the recommended comfort range in all areas, except for the guidance <br /> areas where relative humidity levels were 6 to 27 percent higher than other areas. The higher <br /> relative humidity levels in the guidance area are largely related to a leak that occurred in a <br /> mechanical room near the first floor guidance area and as a result had moistened carpet and other <br /> building materials;this is discussed further in the Moisture/microbial Concerns section of this <br /> report. Relative humidity levels in the building would be expected to drop during the whiter <br /> months due to heating. The sensation of dryness and irritation'.is common in a low relative <br /> humidity environment. Low relative humidity is a very common problem during the heating <br /> season in the northeast part of the United States. <br /> Micro i Moi tore Concerns <br /> In order for building materials to support mold growth, a source of water exposure is <br /> necessary. Identification and elimination of the source of water moistening building materials Is <br />
The URL can be used to link to this page
Your browser does not support the video tag.