Laserfiche WebLink
Town a <br /> 16 Gr ?a.t deck &ad Xo rth <br /> Ma hp e, Massachusetts 026 <br /> April 7, 1997 <br /> D'Agostino Associates, Inc. Str kal vsl y& Hoit, Inc. <br /> 44 Farwell Street 51 North Street <br /> Newton, Ma. 02160 Hingham, Ma. 02043 <br /> Re, Mashpee Town Hall Renovations <br /> Code Violations, Second List <br /> Dear Messrs. Paoletta& Holt, <br /> Each ofvou are cited for the following violations of 780 CMR,The State Building Code as <br /> indicated: <br /> 1. Door L 2 - Floor at door is uneven-and a tripping hazard. D'Agostino <br /> - 2*'-, Mechanical room, lower level - seal pipe openings in extenor.wall. 1atr-line4pentrations <br /> leak and a wail patch is leafing above and into sprinkler system notifr T - . D'Agostino <br /> . Mechanical room, lower level - air handler support,l -D wood in contact with concrete. <br /> D'Agostino <br /> 4. Stair#1 pump room-temporary Ii ht in pump room. 780 C 11x1 R Article 27 -D'Agostino <br /> . Stair#I pump room- no handle or lock on door. D'Agostino <br /> . 780 CMR Article 27 - Electrical -all sub-panels are missing covers and the majority are <br /> missing blank plans. I 'AgostiDo <br /> 7. 780 CMR Article 2 - Mechanical Equipment-excessive diffuser&exhaust noise,Building: <br /> conference rooms,etc. -fault} design or areas are not properly balanced. Heat control <br /> problem- faulty design or balance. Filters are not missing in Air Handler#1. D'Agostino <br /> 8. As-built drawings,operation instruction sets(2), Manufacturer Brochures have not been <br /> submitted. Encyineer must certify systems and their proper operation it appears their operation <br /> is faulted). This is required for all s stemsplurnbing, gas,electrical, FI A ,etc.). <br /> D'Agostino <br /> . Drawing A1. , Detail #1, 2 &.3 - Project Manual,Section 0731 , Fart 2& 3 -This section call <br /> for the removal of the existing shingles and the gutters which were not done. The gutters were <br /> lined and the new shingles installed over the old. The non-compliant work is to removed and <br /> the shingles and gutters are to be installed per contract documents. D'Aostino-70 CMR <br /> Section 127.3 item I(execute work according to construction documents), item 2(failure to <br /> note all pertinent deviations specifically). <br /> 10. 780 CM1 Section 1110.4 - F oof structure over xecutive secretary does not meet ponding <br /> regulation, for structural loads. Scupper required. Agostino <br /> 11. A 1.5 Detail 1 -Due to numerous leaks it is presumed thru-wall flashing was not installed at <br /> the elevator wall nor were weep holes created. D'Agostino <br /> ostino <br /> 12. A2.1 -New wood trim required for the outside of the elevator shaft and stair#2 has not been <br /> properly installed and flashed. D'Agostino <br /> 13. Numerous leaks- leisure services, clerks, administrative secretary, treasurer, roof on 1920 <br /> building and especially in the newly built section. D'Agostino <br /> 14. Ceiling the missing in leisure services. D'Agostino <br /> trekalovsky& Hoit- items#7&8 -780 CMR 127.2.3 (issuance of a substantial completion with <br /> non-compliance of acceptable practices, items 9& l 1 -780 CMR Section 127 2.2 failure to insure the <br /> work has proceeded in accordance with the documents approved for the building permit and failure to issue <br /> corrective directive)and 127.2.3 failure to list pertinent deviations for the approved building <br /> documents), item 1 -780 CMR127.2.1 (plans do not meet the applicable provisions of this code)and <br /> 127.2.3 (issuance ofa substantial completion without noting a code violation) <br />