My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5/9/1981 TOWN MEETING Town Meeting
>
5/9/1981 TOWN MEETING Town Meeting
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2021 9:57:35 AM
Creation date
2/14/2019 2:16:27 PM
Metadata
Fields
Template:
Town Meeting Warrants
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Y <br /> k supervision of the Building Inspector,or take any other which are wired to the low voltage alarm system, th <br /> action related thereto. g y e <br /> Le number and location to be determined by the Fire Chief. <br /> t• SUBMITTED BY These hallway smoke detectors shall be equipped with i <br /> ly THE BOARD OF SELECTMEN at least a nine (9) second delay capacitor and screen. <br /> FINANCE COMMITTEE <br /> Also, if common hallways exist there shall be a pull <br /> DOES NOT RECOMMEND statin trecom- <br /> mended <br /> P ' <br /> o a ether end of the hallway located as recom- <br /> r mended by the Massachusetts State Buildin Code and <br /> Article 34,To see if the Town will vote to amend Section g <br /> a zone panel box in each common hallway.The number <br /> 6, Land Use Regulations of the Zoning By-Law by ad- y' <br />,id din thereto under Subsection L Accessory U of zones and location of the box shall be negotiable. <br /> of g gr ses,a new wither_ this love voltage alarm system i .� <br /> Number 9 as follows: g y n each build- <br /> Zle ing or structure there shall be installed exterior audible <br /> or Fixed or floating piers, wharfs or docks,-both sea- <br /> bells or horns and an exterior rotating beacon light <br /> sonal and year round,not in excess of forty-five feet in which shall be located asrescribed b theFire P by re Chief <br /> overall length from mean low water subject to the and which will be activated b the activation <br /> securing of all necessarypermits from Town State r �' o of any <br /> P o warning device within this closed system.These bells or <br /> Federal governmental units having jurisdiction over horns shall also be installed in the common hallways, <br /> nd t' inland and/or coastal waterways and wetlands." where they exist in an given building or structure. <br />,he an th �' g g <br /> or take y other action thereon. These bells or horns must be loud enough to be heard in E <br /> of U13MITTED BY any room in an unit within an given building S y y g ld�ng strut- <br /> e a ; THE CONSERVATION COMMISSION ture. <br /> ger AND THE HARBORMASTER, In reference e ce to a new single structure with more than <br /> Article 35. To see if the Town will vote to amend the <br /> one dwelling unit, a zone panel box or an announciator <br /> panel tied to this closed low voltage alt <br /> Town By-Laws by adding the following to Chapter 4, arm system as <br /> t <br /> prescribed above and designed to indicate all units <br /> Article 4.6, Section 4.5.x: ' . <br /> within said building shall be installed in a location that <br /> end =� g <br /> E of Y Any new structure containing more than one dwelling is clearly visible from the outside of said building. <br /> pee, incbut <br /> unit to be built in the Town of Mashluding b <br /> be. not limited to structures known as c nd In reference to more than one new structure, each <br /> ria. o om�n�ums,shall structure containingmore than one d <br /> have installed an alarm system so prescribed by the Fire welling unit but <br /> isChief as foil w : not more than five multi-unit structures common to or <br /> her o s within the same complex or project and based on the <br /> Smoke detectors shall be installed on each level in- <br /> Fire Chief s decision with regard to layout of said com- <br /> g' y <br /> s cludang the basement of each unit within the structure plex or project shall exercise one of two options: <br /> as prescribed by the Massachusetts State Building <br /> Code. These smoke detectors shall be local to the unit 1. Install in each building a zone panel box or announ- <br /> and wired on an essential circuit within the unit such ciator panel tied to the closed law voltage alarm <br /> ind as the kitchen circuit. system as prescribed above, and able to indicate all <br /> I of 3 units within said building in a location that is clearly <br /> be. There shall be a rate of rise/fixed temperature heat visible from the outside of said building. <br />,c�� :� detector installed on each level including the basement <br /> 2. Tie all low voltage alarm system as prescribed above, <br /> of each unit within the structure and a prescribed <br />�c�l in all buildings within.said complex or project to a <br /> her number of heat detectors in each attic space over each , <br /> unit depending on the size of the attic. There shall be a common exterior centrally located announciator <br /> fixed temperature heat detector in the room r space Panel easily seen by responding fire apparatus which <br /> Pe o p ce clearly identifies which building in the complex is <br /> which houses the heating plant for each unit or struc- <br /> ture. experiencing the alarm condition. There shall be at <br /> least one telephone lease line which is designed to <br /> These heat dee <br /> A detectors shall be part of a complete, carry an alarm or trouble signal running from this <br /> closed alarm system, local to the entire building or central announciator panel to the Mashpee Fire De- <br /> structure, therefore sounding around and throughout partrnent alarm box. 'k <br /> the entire building or structure. This system will be a <br /> any ° voltage system In reference to more than five new or existing str-uc- <br /> g y with a sixty-hour battery backup. <br /> tures with all or the majority of these structures <br /> The AC <br /> power connection shall connect ahead of the containing more than one dwelling unit and located <br /> Min switch with a locking device and key. The wiring <br /> forth' within the same complex or project,each structure's <br /> �s system shall..be low energy fire alarm wire rated a <br /> at 105 centi a closed low voltage alarm system, as prescribed <br /> and de' above,shall be,tied into a common exterior centrally <br /> Qf If the layout of a particular structure calls for common located announciator panel easily seen b res nd- <br /> P y y Po ; <br /> hallways there shall be smoke detectors in each hallway in fixe apparatus which clear/ indicates which <br /> the Y g PP y <br /> —5— <br /> �', <br />
The URL can be used to link to this page
Your browser does not support the video tag.