Laserfiche WebLink
DEPARTMENT OF THE ARMY AND THE AIR FORCE <br /> AIR NATIONAL GUARD <br /> 1411 JEFFERSON DAVIS HIGHWAY <br /> ARLINGTON, VA 22202-3231 <br /> 24 April 2002 <br /> TO: Richard Joyal <br /> FROM: ANGIC4AT <br /> 1411 Jefferson Davis Highway <br /> Arlington, VA 22202-3231 <br /> SUBJECT: OBSTACLE EVALUATION# 2002-ANE-215-OE <br /> 1. An obstacle evaluation was conducted on# 2002-ANE-215-OE for any impacts to <br /> the instrument procedures at Otis ANGB, MA. It was determined that due to <br /> present obstacles in the area that this tower could be built to 154' AGL (269'MSL) <br /> with no impact to the instrument procedures at Otis ANGB. <br /> 2. Any height above 154'AGL (269'MSL) would raise the TACAN RWY 32 MDA to <br /> 560 vice 520 due to the obstacle location in the final primary surface area. <br /> 3. C4A point of contact is Everett Oakes, COM (703) 607-2389 or DSN 327-2389. <br /> Everett Oakes <br /> Chief Analyst, ANG TERPS <br />