Laserfiche WebLink
elevations for each developable parcel shown 2. Adequate surface drainage and access <br /> on the design plans. for a hauler must be provided. <br /> §174-62.2 Manufactured Home Parks and 3. In the instance of elevation on pilings, <br /> Subdivisions lots must be large enough to permit <br /> steps,piling foundations must be placed <br /> Notwithstanding the applicable provisions of in stable soil no more than ten (10) <br /> the Massachusetts State Building Code within feet apart and reinforcement must be <br /> Zone AE, for new manufactured home parks provided for piers more than six (6)feet <br /> and manufactured home subdivisions and above ground level. <br /> for existing manufactured home parks and <br /> manufactured home subdivisions where the §174-63 Development within V Zones <br /> repair, reconstruction or improvement of the <br /> streets,utilities and pads equals or exceeds fifty No land within areas designated as V(velocity) <br /> percent(50%)of the value of the streets,util i ties Zones on the Federal Emergency Management <br /> and pads before the repair, reconstruction or Agency Flood Insurance Rate Maps shall <br /> improvement has commenced: be developed unless such development is <br /> demonstrated,by the application,to be located <br /> 1. lots are to be elevated on pilings or a landward of the reach of the mean high tide. <br /> flood compliant solid wall foundation so Notwithstanding the applicable provisions of <br /> that the lowest floor of the manufactured the Massachusetts State Building Code, all <br /> home will be above the base flood new construction and substantial improvement <br /> elevation in compliance with the within the V Zones shall be elevated on <br /> Massachusetts State Building Code; adequately anchored pilings or columns and <br /> securely anchored to such piles or columns <br /> 2. adequate surface drainage and access for so that the lowest portion of the structural <br /> a hauler must be provided; and, members of the lowest floor, excluding the <br /> pilings or columns, is elevated above the <br /> 3. in the instance of elevation on pilings, base flood elevation in compliance with the <br /> lots must be large enough to permit Massachusetts State Building Code, and <br /> steps,piling foundations must be placed certified by a registered professional engineer <br /> in stable soil no more than ten (10) or architect that the structure is securely <br /> feet apart, and reinforcement must be anchored to adequately anchored pilings or <br /> provided for pilings more than six (6) columns in order to withstand velocity waters <br /> feet above the ground level. and hurricane wave wash. <br /> The following shall be prohibited <br /> §174-62.3 Manufactured Homes not in Parks or within said V Zones: <br /> Subdivisions <br /> 1. Any man-made alteration of sand dunes <br /> Notwithstanding the applicable provisions of which might increase the potential for <br /> the Massachusetts State Building Code, in all flood damage. <br /> manufactured homes to be placed within Zone 2. Use of fill for structural support for new <br /> AE but not into a manufactured home park or construction or substantial improvement <br /> manufactured home subdivision: of structures. <br /> 3. Manufactured homes,except in existing <br /> 1. Manufactured Homes must be elevated manufactured home parks and existing <br /> on pilings or on a solid wall foundation manufactured home subdivisions. <br /> with flood openings so that the lowest <br /> floor of the manufactured home will §174-64 Unnumbered A Zones <br /> be above the base flood elevation in <br /> compliance with the Massachusetts In A Zones,in the absence of FEMA BFE data <br /> State Building Code. andFloodway data,the Building Commissioner <br /> shall request from the proponent's registered <br /> 88 <br />