My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1981-1982-TOWN MEETING RECORDS
TownOfMashpee
>
Town Clerk
>
Minutes
>
TOWN MEETING
>
TOWN MEETING CORRESPONDENCE
>
1980-1989
>
1982
>
1981-1982-TOWN MEETING RECORDS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2019 2:41:56 PM
Creation date
11/17/2016 3:35:02 PM
Metadata
Fields
Template:
Mashpee_Meeting Documents
Board
TOWN MEETING
Meeting Document Type
Minutes
Meeting Date
12/31/1982
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
q <br /> 3 <br /> ARTICLE 35 To see if the Town will vote to amend the Town By- haws <br /> by adding the following to Chapter 4, Article 4.6, Section 4.6.6: <br /> Any new structure containing more than one dwelling unit to be built <br /> in the Town of Mashpee, including but not limited to structures known <br /> as condominiums, shall have installed an alarms stem so 3 <br /> by the Fire Chief as follows: y prescribed <br /> Smoke detectors shall be installed on each level including the <br /> basement of each unit within the structure as prescribed by the <br /> Massachusetts State Building Code. These smoke detectors shall <br /> be local to the unit and wired on an essential circuit within the <br /> unit, such as the kitchen circuit. <br /> There shall be a rate of rise/fixed temperature heat detector <br /> installed on each level including the basement of each unit ' <br /> within the structure and a prescribed number of heat detectors <br /> in each attic space over each unit depending on the size of the <br /> attic. There shall be a fixed temperature heat detector in the <br /> room or space which houses the heating plant for each unit or <br /> structure. poi <br /> These heat detectors shall be part of a complete, closed alarm , <br /> system, local to the entire building or structure, therefore <br /> sounding around and throughout the entire building or structure. <br /> This system will be a low voltage system with a sixty- hour back- <br /> up. The AC power connection shall connect ahead of the main switch �f <br /> with a locking device and key. The wiring for energy fire alarm <br /> wire rated at 106 centigrade. <br /> 3p I <br /> If the layout of a particular structure calls for common hallways <br /> thereshall be smokedetectors ineach hallway which are wired to the <br /> low voltage alarm system, the number and location to be determined <br /> by the Fire Chief.These hallway smoke detectors shall be equipped <br /> with at least; a nin69) second delay capacitor and screen. Also, if <br /> common hallways exist there shall be a pull station at either end <br /> of the hallway located as recommended by the Massachusetts State <br /> .Building Code and a zone panel box in each common hallway. The <br /> number of zones and location of box shall be negotiable. <br /> Within this low voltage alarm system in each building or structure <br /> there shall be installed exterior audible bells or horn and an <br /> exterior rotating beacon light which shall be located as prescribed <br /> by the Fire Chief and which will be activated by the activation of <br /> any warning device within this closed system. These bells or horns <br /> shall also be installed in the common hallways, where they exist in 'i.r"' <br /> any given building or structure. These bells or horns must be loud �' � � <br /> enough to be heard in any room in any unit within any given build- <br /> ,i e <br /> ing structure. <br /> s,� i <br />
The URL can be used to link to this page
Your browser does not support the video tag.