Laserfiche WebLink
4 TOWN of MASHPE <br /> BOARD OF' HEALTH <br /> MEETING <br /> March 2 , 1989 <br /> Meeting Called to order at 3:00 p.m. <br /> Members present: George R. Costa, Stephen J. Greelish and Roland L. Wilson <br /> THE TAPE IS NOT PART of THE MEETING, IT IS FOR THE PURPOSE of TRANSCRIBING <br /> MINUTES. <br /> Mr. George R. Costa, Chairman <br /> 1 . ) Warrants signed <br /> 2. M . Greelish motioned to accept the minutes of March 20, 1989, Mr. <br /> Wilson seconded, all agreed. <br /> : . Proposed septi.. upgrade plan, Benchmark Erg. for Greenberg ,, Santuit <br /> Lane - r. McQuaiTifformed the Board no addition or alterations are <br /> proposed, the owners intentions are to upgrade the existing system. <br /> Mr. McQuaid explained to the Board variances requested are from well <br /> to proposed leathing , well to abutting l ea Cbf i e l , sideline and septic <br /> to abutting wells across the street. Mr. McQuaid stated D.E. .E. <br /> approval is required and commented due the size of the lot,, these <br /> are the maximum distances obtainable. He explained the engineer is <br /> requesting the board' s imput as to whether or not plans should be sub- <br /> mitted .to D.E. .E. and -explained the system is in fa1iure the only <br /> option available 'is re-locate the well however abutters are not favor- <br /> able <br /> a or- <br /> able to this proposal . <br /> Mr. Costa recommended a- public hearing and requested tine applicant <br /> to notify abutters. <br /> 4. ) Variance request, flow diffusers, Cape & Islands for~ Gutterman, 46 <br /> Popponesset Island Road - Mr. McQua17 commentedto ,the Board that <br /> he would recommend -flow diffusers due to the close proximity of -the <br /> wetlands. Mr. McQuaid stated all abutters are receiving Highwood <br /> Water and explained ground water~ was*encountered 15' down, flow <br /> diffusers are proposed as a safety factor as well as the fact that <br /> seer lines tomirig out of the foundation are below the foundation <br /> level and are coming out of e l e -a ion 9 to the flow d i ff u ser at e l e- <br /> ri <br /> vatio7.9, a pit would not "'-fit between that and the ground water <br /> which is the rea on fgrft proposed flow diffusers. - -Mr. McQuaid <br /> suggested a reserve area be installed with a bull run valve. <br /> Mr. Greelish motioned to grant the variance as requested with the <br /> st i pu l at i.on a reserve area and bull run valve be installed along <br /> with flow diffusers, Mr. Wilson seconded, all agreed. <br /> . Subdivision plan, PimliCo Heights, well and septic locations -- <br /> Mr. McQuaid explained to the Board that the developer has sub- <br /> mitted revised plans delineating individual septic andwe'll loca- <br /> tions for the subdivision as requested by this Board. Mr. McQuaid <br />