r <br /> .. 7:30 Jeff F yther, Ess Design T'Itle V Variance— 166 Water Way <br /> Jeffrey F yther, Civil Engineer with BSS Designs in Falmouth, introduced himself to the Board, <br /> stating that he was representing Todd and Dena Pavone. In a letter from Mr. i yther to the <br /> Board of Health dated 6/28/11, the following three variance requests were listed: <br /> a Reduction of system location setbacks otherwise established in 310 CIVIL 15.211 for <br /> property lines... - <br /> "1. septic Tank is less than 10' to side lot line ' shown on the plan) <br /> .. SAS is less than 10'to street 1ayout 11 n 3.4' shown on the plan) <br /> b Reduction of system location setbacks from cellar wall, or slab foundations <br /> 1. SAS is less than 2 'to the crawl space wall 1 a' shown on the plan) <br /> g -Reduction eduction of system location setbacks from surface waters, salt marshes, inland and coastal <br /> banks... i <br /> 1. SAS is less than 100'to the vegetated wetland 9 'to marsh) <br /> The lever further requested approval for alternative technology in the form of Singulair Model <br /> 960 NR/500 Advanced Treatment System. <br /> Glen Harrington commented that this property has an existing four-bedroom dwelling which <br /> shall be razed and rebuilt. The existing septic system (tank and pit) is located on the water side <br /> of the dwelling with the pit most likely discharging directly into the groundwater. There is an <br /> existing approved application for the property which occurred on 8112108 but the plan has <br /> changed with the above-listed new variance requests. The pian consists of a proposed <br /> Singulair septic tank which houses a Model 960 NFA denitrification system, distribution box and <br /> an SAS of 3-33' x 2'x2' leaching trenches. The architect would like to charge the crawl space <br /> in front of the house to a cellar wall, which means that a membrane should be provided. Glen <br /> recommended approval of the requested variances with the following-conditions: <br /> 1 the plan requires a PE or RS stamp <br /> 2 membrane to be installed between SAS and cellar wall <br /> 3) O&M to include sampling/analysis for TN quarterly for 2 years from the D-Box. <br /> 4 Singulair approval based upon a General a Approval. <br /> Burton Caplan made a motion that the Board approve the variance request form submitted for <br /> 166 Water Way with the four variances outlined in the letter to the BOH from Jeffrey F yther <br /> dated 6128111, subject to the following: all necessary Conservation Commission approvals, <br /> O&M sampling anal sis for TIN quarterly for 2.years from the D-Box, and Singulair use based <br /> upon a General Use Approval. calliope EglofF seconded the motion. The motion was <br /> unanimously approved. <br /> 7:45—Peter McEntee, Engineering.Work , Inc.—Title V Variance—1 4 Fels Pond Road <br /> Peter McEntee with Engineering Works,, Inc., introduced himself to the Board as representing <br /> his client, Jeffrey Cohen, the prospective buyer of the property at 154 Fells Pond Road. Mr. <br /> McEntee requested that the following three variances be considered for the purpose of a Title <br /> Septic Upgrade at 1 4 Fells Pond Road': <br /> ry <br /> 1 A ' variance, septic tank to property lire (side), for a 5} setback <br /> 2) A ' variance, S.A.S. to cellar wall, for a 14' setback <br /> 3 A 1' variance, septic tank to cell a wwalI, for a 9' setback. <br /> 2 <br />