Laserfiche WebLink
Mashpee Public Lire"' <br /> P.O. Box 657 <br /> l ashpee, Ufa 0264 <br /> Circulation for February 2006 was 10,452 items, That exceeds last February by <br /> 576 items, our year -to-date total Is 90,228 items. <br /> The early part of February was very rha-Ilenging. We had two people out sick for <br /> a geek, overlapping another staff person's vacation. Debbie .Umina was <br /> reactivated to Delp us through the worst pert of the shortage. We continued to <br /> have people out sick throughout the month but we're able to cope without extra <br /> help because it was one person at a time. Hopefully, the worst is passed and <br /> everyone is healthy again. <br /> I have spent much of my time this month involved in the final design development <br /> of the new library. We've been meeting b reekly to fine tune the basic design <br /> that.we started with. We'are currently at a good place with the design but the <br /> layout is still subject to change. The architect has been awaiting a code change <br /> which would eliminate the need to have two emergency stairs in the building. The <br /> current design reflects this. if the code change isn't finalized within a month: he <br /> ►ri if have to insert the second set of stain into the plan. This will alter the size of <br /> staff work space and will require relocating the upstairs restrooms. I'm hoping the <br /> code change comes through and we are able to retain the current layout. The <br /> staff and ] have spent several hours reviewing the plans and have come up with <br /> a layout that works very well operationally. The staff and the committee are very <br /> plesed with the.design so I'm hoping we don't have.to alter it. <br /> The Mechanical Engineers, Garcia, G luska and DeSouza (GGD), reviewed five <br /> types of heating. systems and recommended that we use a heat induction <br /> system. This system uses a single fan to craw fresh air in and high pressure <br /> nozzles throughout the building circulate the heated or cooled air. The <br /> advantages to the system are fewer roving parts, lower installation costs, <br /> quieter, more comfortable, and very easy to maintain. The unit is very energy <br /> efficient so the installation and operation rave in as the most cost effective for <br /> our project. <br /> The committee had a lot of questions.for the engineers and expressed a desire to <br /> visit a site that actually had an induction HVAC System. The system has been <br /> used in y � <br /> Europe for man ears but had only been used in the U.S. for about <br /> years. GGD arranged a site visit to a school in Plymouth and had the Customer <br /> Service e F epresentative meet us there to answer questions. We were very <br /> impressed with the system and the subcommittee recommended incorporating <br /> this system into our design. The P&CC met on February 26th and voted to d with <br /> y g <br /> the induction system. I've inuded an article from the Mashpee Enterprise which <br /> more fully explains the benefits of the induction system. <br />