Laserfiche WebLink
protect existing vegetation is indicated , what is existing vegetation? <br /> Phil said they will identify limit of where protection takes place. <br /> - where will well and well pump be located? <br /> Mechanical - electric heat i'ng units? <br /> They will only be in the electrical closets themse1ves. <br /> Paul said there will be sufficient heat from the transformers , the units <br /> are a waste of money . Everyone agreed to get rid of themb <br /> weatherproofing duct work above the roof, Will be in the specs . <br /> #1 S Prevent cross-flow. Mechanical engineer will review this issue, <br /> pg. 3 1 , SMMA provide details so not to leave to contractors discretion:. <br /> Everyone agreed to eliminate drains at emergency shower. <br /> pg 6 Sink connections only? Phil said sinks will go with the laboratory <br /> work equipment subcontractor to provide better~ coordination <br /> Paul said the drawings show duel connection of the water line on the site. <br /> That issue should be brought up with the Eire Chief. It is an expense the <br /> project cannot afford <br /> PROPOSED CONSTRUCTION COST REDUCTION I:TET <br /> Daedalus presented a revised estimate, dated 10/25 , changes included : <br /> - substructure- $35 , 502 decrease <br /> structure- $282 , 297 increase <br /> - uteri or cladding- $600a000 increase <br /> - interior partitions - $2317866 decrease <br /> vertical movement- $19 , 038 increase <br /> interior finishes- 56 009 i ncrease <br /> fitting and equipment-- $211 , 416 increase <br /> e 1 ect r i ca 1 - $107 , 309 decrease <br /> mechanical- $45O ,Q73 decrease <br /> site development- $151 , 961 increase <br /> Joel see1ey said the total decrease over the previous esti mate i's 044,00o . <br /> Total cost starting point us $23 ,414 , 559 which is ars overrun of $3 , 2547559 . <br /> Chartwell figured the square footage at 182,000. This document says it is <br /> 184, 000, which Ray says is not correct. The building is on CAD, which says <br /> it is ;just under 183,000 sq feet. <br /> Daedalus explained their calculations were taken off by hand and he i s not <br /> surprised by a small deviation like this. <br /> Ray said if you deduct the 1 ,000 sq feet oast your can reduce $200, 000 right <br /> off the top. <br /> Ed asked if everyone wants to go with this estimate or come to ars agreement <br /> on some amount to reduce it by? <br /> Torn Wren noted it i s only a 1 deviation . It will not rake an appreciable <br /> difference. Everyone can keep in mind that it is there. <br /> Bob noted there will be a variation between contractors bidding the job. <br /> The committee agreed to work with the estimate as presented. <br /> Torn Wren highlighted Chartwell ' s comments (as presented In status report <br /> 1g) IP <br /> The September estimate stood at $21 , 3 million after deduction of $2 .47 in <br /> value management savings from the schematic design estimate of $23 , 8 <br /> million. There is now a $3 . 28 million overrun. The Committee is looking <br /> at some hard decisions to reach the target of $110 per sq foot. The <br />