1 <br /> %N00 <br /> %Jti ofMashpee <br /> 16 Great Zeck �oad V <br /> Mashpee, Massachusetts 02649 <br /> Apri 18, 1997 <br /> 1 'Agostino Associates, Inc. Strekalovsky& Hoit, Inc. <br /> 44 Farwell Street 51 North Street <br /> Newton, [via 02160 Hingham, Ila. 043 <br /> Ike: Mashpee Town Hall Renovations <br /> Code Violations <br /> Dear Messrs. P oletta& Hoit, <br /> Each of you are cited for the following violations of 780 Cif (The State Building Code)Section <br /> 12 and the sections listed of 521 C1 (Architectural Access Board, Rules and Regulations)as indicated: <br /> 1. Lower level hall at door 145 -20.6.1 - fire extinguisher protrudes beyond 4 inches. <br /> 2. Mair 9 1 -20.7-headroom under stair,cane detection guard required. <br /> 3. Mair##1 -26.1 1. -no hardware or hazard indication for pump rourn. <br /> 4. Lower level hall,doors L18, L05& L02-26.1 1. -no hazard hardware. <br /> . Lower level men's room-30.9.2-sink at 34 %inches high exceeds height requirement. <br /> 6. Lower level men's room-30.12-soap dispenser at 49 inches exceeds height requirement. <br /> 7. Lower level woman's room-30.12-soap disperser at 49 inches exceeds height requirement. <br /> . Lower level stair#2-20.7-headroom under stair, cane detection guard required. <br /> . Lower level meeting room- 14.5.2 -a portable assistive listening device is required. <br /> 10. Upper level men's room-30.9.2 -sink at 4 ',t inches exceeds height requirement. <br /> 11. Upper level men's room-30.12-soap dispenser exceeds height requirement. <br /> 12. Employee lounge-32.6,32.2-knee space required under sink and exceeds height <br /> requirement. <br /> 13. Employee lounge-32.2-counter exceeds height requirement. <br /> 14. Employee lounge-32.3 -wall cabinets exceed height requirement. <br /> 15. Employee lounge-32.7.3 -sink exceeds required depth. <br /> 16. Main floor electrical room-door has no hazard hardware. <br /> 17. flair, level door 113 -26.6.3 -does not meet clearance requirernent for access to door with <br /> heater in the way. <br /> 18. Lower level storage-28.1 -elevator access required. <br /> 19. Main level meeting room- 14.5.1 -a permanent assistive listening system required. <br /> I 'Aostino is cited for all the above code violations. H o i t is cited under 780 CMR Section 127.2.3 <br /> (issuance of substantial completion without noting code violations). You are hereby given notice ofthe <br /> above violations per section 121 and are ordered to abate all violations or have a schedule of abatement <br /> within three weeks. This is not a complete and final list of violations. <br /> Sincerely, <br /> ry <br /> William F. Hauck <br /> Inspector of Buildings <br />