My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1/1/1957 Zoning & Town Bylaws
TownOfMashpee
>
Town Clerk
>
Zoning Bylaws - History
>
1/1/1957 Zoning & Town Bylaws
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2021 3:25:38 PM
Creation date
2/2/2021 12:30:45 PM
Metadata
Fields
Template:
Mashpee_Meeting Documents
Board
ZONING BY-LAWS
Meeting Document Type
Bylaws
Meeting Date
01/01/1957
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` -3- <br /> built <br /> 3`built to receive girder ends , or cement filled steel columns ma-,r be used. <br /> Para. 7. All areas under buildings must be accessible with a minimum <br /> clearance of 20 inches and be ventilated in two exterior walls , 'S <br /> Para. 8. No wooden structural member shall be closer than one inch to <br /> 6-the chimney, and -whenever. iooden forms or supports are used in the con- <br /> struction chimneys or fireplaces , then shall be removed within two weeks <br /> after masonry is laid. <br /> Para. 9 . Sizing and spacing of girders shall be in accordance with <br /> Tables, I, II , III , IV appended . <br /> Para. 10 ' ood floor joists . 1. 1")here joists frame into side of <br /> wood girders , mel,al hangers or a bearin - stri s piked to the <br /> g p x girder must <br /> be used., 2 . Floor joists framed into masonry walls shall have at least <br /> a,four inch bearing and a three inch fire bevel cut . 3 . Floor joists x' <br /> shall be doubled under all partitions running parallel to the floor joists . k <br /> 4 . All headers over four feet long shall be doubled. 5.. Floor Joists � <br /> shall be cross bridged when span exceed eight feet . At least one by three ' <br /> inch or stronger stock shall be used. <br /> Para. 11. Wood Rafters . 1. 1'.'ood Rafters . 1 . Truss construction may <br /> be used provided it is of a strength comparable with Table IV and is „h <br /> approved b-- tie Building Inspector. 2 . Collar ties riot less than 2x4 or <br /> lx6 inches shall be used for all sloping rafters . <br /> Para. 12 . Exterior gall studs . 1. Studs shall not be less than two <br /> inches by four inches placed not more than sixteen inches on center . <br /> 2. Headers over all openin s shall be doubled and shall be at least the <br /> following: , ( a) up to 31 -2 2x41s (b ) 31 to 52-1 -2 2x61s on edge . ( c ) 5 -' <br /> to' 71 -2 2xE•ls on edge . ( d) over 71 -2 2x101s on edge . 3 . In lieu of headers , <br /> approved truces may be used . 4. Studs in exterior frame walls may run <br /> froom still to roof line provided they do not exceed twenty feet in length. <br /> 5 . Studs shall not be spliced. 6. Floor joists on exterior walls shall <br /> bear on at least a one inch by six inch ribbon let into the face of the <br /> studding. Joists bearing on such ribbons shall be securely nailed to the <br /> studs . - <br /> Para. 13 . Plates : All top plates shall be not less than two inches <br /> by four inches doubled, which shall lap at all corners and joints or butes . <br /> Para. 14. Interior Partitions . 1. All bearing partitions shall be <br /> not less than two inches by four inches set the four inch way, and not <br /> more than sixteen inches on center. 2 . All openings in bearing partitions <br /> shall have double headers framed as required in exterior openings . 3 . Top <br /> Plates for bearing partitions shall be 'doubled. <br /> Para. 15 . Notching of Timbers : Notching of joists to facilitate the <br /> installation of pipes and ducts may be permitted with the following in- <br /> stallation s : 1. Top and bottom edges may be notched not to exceed one sixth <br /> of the joist depth. Notching will not be permitted in middle third of any <br /> joist span. 2 . If cutting of a floor joist is necessary, a header the full <br /> depth of the joist shall be cut in to support the ends of the joists . <br /> i' <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.