Laserfiche WebLink
r <br /> e; <br /> .4;t <br /> i r <br /> Eldredge, <br /> MEMO RANDUM <br /> Surveying & Engineering <br /> i. <br /> 1038 Main Street, Chatham, MA 02633 <br /> Telephone: [50819454965 � <br /> Fax. [608] 946-6885 1Pi, <br /> To; Mike Roberts By Fax 1-508-539-3951 MAY x � <br /> From; Terry W. Eldredge <br /> t <br /> Date: May 20 1999 <br /> Subject: Windchirne P6int Project <br /> t;E � <br /> l viewed the site last night. P.A. Landers appears:to have <br /> �� � done an excellent -,of , <br /> grading the sub-base and placing 9 Inches of reclaimed asphalt (T-ba-se). l noticed that <br /> a grader is at the site and l assume that the will be grading]� � ad g the bane today. � <br /> V <br /> abaerved the following that needs attention: ,t <br /> I. The area around the catch basin at the roundIn - <br /> .g��here v�lindchrn�e Drive �• <br /> rrtersects <br /> with Snowy, Egret Drive (near building needs.to be du <br /> out by hand and T-base <br /> placed around the same. <br /> 2. The area around <br /> the catch basin on Snowy Egret Drive (near building 39) needs to <br /> be dug out by hand and TRbase laced around h& , <br /> l� . t same. <br /> I one frame and grate needs to be installed. l can't read my notes and l don't <br /> remember which set of catch basins it was at. <br /> 4. The grade just beyond the how point in <br /> Snowy Egret Drive appears to be low. it <br /> seems to match the grade stake, so either m eye is off or the grade <br /> . Y Y � de is incorrect on . <br /> the stake. Also, the finished grade in this are <br /> . � g a must match the rlrn of the pull box as , <br /> a. sidewalk � <br /> 'is proposed in this area. l just spoke with Steve. Steve informed <br /> Billy � med me that <i <br /> y might have used the centerline r :gyp <br /> coo <br /> grade to set the frame and grate with. This •- <br /> would account for why the grade at the next station appears �o �� low. �ssi`in'"ti ear +e ing <br /> i <br /> s s correct l want to hold the e elevation <br /> that this ' on the frame and rate <br /> � and raise the <br /> corresponding grade of the road at the next statioh byapproximately <br /> o.� feet. This , <br /> Will match the grade of the rim of the pull box <br /> � better. <br /> . Also the ; . <br /> f e pre-existing right frame and rate for the leaching cat y g g catch basin an <br /> Windchime Drive near build <br /> ing 34 appears to.have been hit. l don't know if it broke , <br /> the concrete a r e that held � <br /> g s the frame and grate in dace, if so this should be <br /> checked. <br /> , <br />