Laserfiche WebLink
INTRODUCTION <br /> The site topography is relatively flat, and according to the proposed site plan ranges from <br /> approximately 44 feet to 48 feet in elevation. As the site is relatively flat, ensuring the <br /> proper grade around each home and directing the water to desired locations requires <br /> careful planning and implementation. <br /> During a recent Transition Study performed by Criterium-Duclka Engineers (dated June 8, <br /> 2022), it was noted that throughout the property there were homes which did not have <br /> concrete extending 6" above the finished grade. MA Current code (780 CMR 9th Edition), <br /> which references the IBC 2015 requires in section R404.1 .6 Height Above Finished Grade <br /> that "concrete and masonry foundation walls shall extend a minimum of 4 inches where <br /> masonry veneer is used and 6 inches elsewhere." This is included in codes to reduce <br /> damage from splashback (where water impacts the ground and splashes onto the portion of <br /> the house next to it, potentially causing damage in the long term) and minimize potential of <br /> termite and wood eating insect damage. <br /> The siding manufacturer (James Hardie brand siding was noted as the brand of siding used) <br /> also recommends installation of the siding 6" above the finish grade. <br /> The Cottages Phase 111 2 <br /> Mashpee, MA AENGINEERS <br />