Laserfiche WebLink
damage <br /> • minimally mulch <br /> area where siding is <br /> <6" above grade <br /> 16 Yes Yes • Grade appears to • re-grade to pitch <br /> Rosewood pitch towards#16 away from homes <br /> Circle. Rosewood Circle. and have siding <br /> • Siding less than 2" clearance <br /> above mulched bed • annually <br /> inspect/treat for <br /> termite and water <br /> damage <br /> • minimally mulch <br /> area where siding is <br /> <6" above grade <br /> 18 Yes Yes • Mulch within —1.25" • re-grade to pitch <br /> Rosewood of siding away from homes <br /> Circle • Eroded area in and have siding <br /> mulch appears to clearance <br /> indicate water • design and install <br /> flowing under drywell <br /> structure • annually <br /> inspect/treat for <br /> termite and water <br /> damage <br /> • minimally mulch <br /> area where siding is <br /> <6" above grade <br /> mailbox Yes Yes • Grade appears to • re-grade to pitch <br /> kiosk slope towards away from kiosk <br /> mailbox kiosk • raise up the kiosk <br /> •Trim on bottom of structure to ensure it <br /> mailbox kiosk in is minimum of 6" <br /> poor condition above grade. <br /> • Replace water <br /> damaged <br /> components <br /> 22 Yes Yes • emergency egress • re-grade to pitch <br /> Rosewood well--water appears away from homes <br /> Circle to still flow towards and have siding <br /> well despite drain clearance <br /> installation • recommend to clean <br /> • Grade appears to gutter drainage <br /> The Cottages Phase III 8 <br /> Mashpee, MA <br /> ,A' , f ' <br />