Laserfiche WebLink
SS <br /> D 0s I G N <br /> July 17, 1998 <br /> Board of Health LAND LJRVEYINl; <br /> _ VI NGINEERIMr.i <br /> 16 Great Neck Road North BOARD L � ) CAFE AHrHITEC 101,1 <br /> Mashpee, MA 02649 <br /> WIN Ucsip,11mW[ ,rated <br /> Ifi-�hatllarfnr Irc Ii.ilr,liir.if <br /> Re: Mashpee Health Regulations - Variance I;=111 u,111n.nl is,a luiarin ll'j-111 <br /> 51)6 54 XSlh t;ic 7i15,j-Iy'n?I+ <br /> Applicant: New Seabury Co. <br /> Lot K(#6) Aunt Jane's Road, Mashpee, Massachusetts <br /> Dear Board Members: <br /> Enclosed please find two (2) copies of a Plot Plan dated July 17, 1998, which is a revision of a <br /> plan prepared by Levy Eldredge & Wagner for the above referenced project and filed with your <br /> Board in March of 1995. This project is to construct a three bedroom house and subsurface <br /> sewage disposal system on Lot K as shown on the Site Plan. <br /> The proposed system as shown is in compliance with the 1978 version of Title V, but does <br /> require a variance under the Mashpee Health Regulations to site a soil absorption system within <br /> 150' of a well used for drinking water. The State requirement under both the 1978 and 1995 <br /> versions of Title V is 100' between a well and a soil absorption system. <br /> The well in question is located at #59 Uncle Edward's Road. The exact location has not been <br /> disclosed by the owner of the property, but for the purpose of this plan we have presumed that <br /> the well is located inside the house, as was the practice in the past. This presumption is borne out <br /> by the fact that several other wells in the area are in the cellar of the house. Some houses have <br /> kept their wells but can only use them for outside watering. <br /> The small lot sizes make full compliance impossible. The components of the septic system are <br /> as far as possible from the well without requesting a variance from lot line setbacks. Even if a <br /> variance from lot line setbacks were granted, the system would still not be 150' from the well. <br /> There is a public water system in the area and house #59 and one other are the only two lots in <br /> the area which are not connected. The other house is at #14 Greenwood Road and the well is far <br /> enough away so as to not affect the siting of a septic system on this lot. <br /> Thank you for your consideration of this request for a variance, if you have any questions, please <br /> call me at 540-8805 or Michael Grotzke at 539-0800. <br /> Sincerely, co G <br /> Design, Inc <br /> _ 0C:) <br /> of . R her P.E. a r> <br /> crs <br /> cn rat <br /> —a m <br />