Laserfiche WebLink
➢ Representative: Self <br /> Project Details <br /> • Proposed construction of a one-car garage on a pre-existing footprint <br /> • Involves closing in two walls under an existing overhang that has a living room above <br /> • Plan includes adding a garage door, a 6-inch concrete pad, and two walls <br /> Flood Zone Considerations <br /> • Property is in AEI I flood zone <br /> • Flood vents required, confirmed by Building Commissioner, but not shown on submitted <br /> plans <br /> • Grade elevation at the house is between 8-10 ft, approximately I foot below flood <br /> elevation <br /> • 5/8 sheetrock specified in the plans is not allowed in the flood zone <br /> Additional Project Details <br /> • Crushed stone driveway will continue to the garage apron <br /> • Cobblestones will be installed on the side, consistent with existing features <br /> • The project is far from the resource areas, except for the flood zone <br /> • Existing utilities (condenser) under the house will need to be relocated above the flood <br /> elevation <br /> ➢ Building: Application for ZBA relief has been filed. <br /> Motion <br /> • Mr. Cook made a motion for a negative determination. Mr. Sahl seconded the motion. <br /> • Roll Call: Mr. Cook(Yes), Mr. Sahl (Yes), Ms. Godfrey (Yes), Mr. Colombo (Yes) <br /> o Motion passed unanimously <br /> Documents provided: Self;Request for Determination of Applicability <br /> RDA 7 Manitoba Road,Danielle R. Ayotte and Davis A. Ayotte, Trustees, Danielle <br /> R. Ayotte Trust—2012 <br /> ➢ Representative: Engineering Works, Inc <br /> Project Details <br /> • Proposed septic system upgrade in an open area without removing existing vegetation <br /> • Compliance with all Board of Health requirements without variances <br /> • Work to be conducted outside the existing arborvitae hedgerow <br /> Technical Discussion <br /> • Submission of nitrogen calculations indicating a reduction <br /> • Percolation test results showing a rate of 4 minutes per inch, allowing the system to <br /> function above groundwater levels <br /> 4 <br />