My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1994 JUL-DEC-HIGH SCHOOL BUILDING COMMITTEE
TownOfMashpee
>
Town Clerk
>
Minutes
>
SCHOOL COMMITTEE
>
HIGH SCHOOL BUILDING
>
1990-1999
>
1994
>
1994 JUL-DEC-HIGH SCHOOL BUILDING COMMITTEE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2016 7:15:21 PM
Creation date
11/17/2016 3:30:54 PM
Metadata
Fields
Template:
Mashpee_Meeting Documents
Board
SCHOOL
Meeting Document Type
Minutes
Meeting Date
12/31/1994
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
182
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Committee had asked DeFao Wait and Pare to downsize the plant. <br /> Janice asked what the additional cost is for this change? <br /> Bob said there is no impact to the Committee. <br /> Bill asked if DFP had any legal recourse? <br /> Paul said they have agreed to withdraw. <br /> ** All members were in favor of the motion 5-0.** <br /> ** Joe made a motion to ask SMMA to contract with Woodard and Curran <br /> to design a 15 , 000 gallon per day sewage treatment plant for the <br /> high school . Merry Sue seconded the motion. All members were in <br /> favor 5-0.** <br /> The Committee will send a letter to the Selectmen notifying them of this <br /> decision. <br /> TAMS DESIGN PEER REVIEW REPORT - Shannon Scarlett <br /> Ms. Scarlett said the drawings have come a long way and looked good . She <br /> highlighted the key issues from her review. <br /> Pg. l - Fire protection needs to be looked at, there are inconsistencies <br /> from 1 floor to the next. <br /> How will the 2 hours enclosure be achieved in the cafeteria? <br /> Phil Pennelli does not think the 2 hour requirement must be met for the <br /> cafeteria - it is an incidental use. That also applies to the library. If <br /> it is not considered an incidental use, they have a fallback position . <br /> Ray agreed. The library is even more so an incidental use, it will not be <br /> a place of assembly. <br /> - Internal location of Auditorium, the corridor is acting as an egress for <br /> the auditorium and she thinks it will have to be sprinklered . The same <br /> condition applies to the gym. <br /> Joe asked if the Building Inspector has looked at the egress? <br /> Phil has met with the Building Inspector. A secondary means out from the <br /> stage (south) was discussed . <br /> Pg. 2 No drop off in front of the building for the students . <br /> Dan reviewed the site plan and the options available to parents. <br /> Shannon asked if the road should be widened to accommodate cars that have <br /> stopped for drop off? <br /> Dan said the road is already 16 feet wide, it is wide enough for that. <br /> Paul suggested there be signs in the front of the building saying no buses <br /> are allowed. <br /> Shannon asked about the handicapped parking. Dan reviewed those locations. <br /> Shannon asked about the parking count and zoning requirement? <br /> Dan said there is no " rate' requirement in the bylaw for schools. They will <br /> request a variance for the parking stall size. <br /> - The sidewalk parallel to the entrance road is only 4 feet wide - to <br /> narrow for pedestrians and bikes. <br /> The Committee does not expect much pedestrian traffic to the school . <br /> Paul asked Dan to re-consider this, it is too narrow. Will talk about it <br /> during the cost discussion . <br /> - Seniors Walk is not shown? It has been eliminated . <br /> - Is there storage for field and maintenance equipment? Bob explained there <br /> will be a double bay added at the STP and they will provide a building for <br /> field equipment but it is not yet shown on the plan. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.