Laserfiche WebLink
storm water management systems and within 50 feet of any proposed buildings, , <br /> along with sufficient spot -grades to -adequately show the direction of storm water <br /> runoff, including at transition points, top and bottom of-vertical curves, entrances, <br /> high points, low points and gutter lines, <br /> g types of ground cover and any other precautions to stabilize slopes, <br /> h existing trees over teen 10 inches in diameter at breast height and whether they are <br /> proposed to be retained or removed, <br /> 0 water-courses, <br /> j drainage, <br /> k) utilities, <br /> l landscaping, <br /> gym) trash collection facilities and <br /> n other proposed features <br /> at a scale of 1 inch = 40 felt, with a " x 36"" index sheet at 1 inch = 100 feet or at <br /> another appropriate scale if the entire site can not b . shown on one sheet at the 1 inch -_ <br /> 100 feet scale; <br /> 8. when a project is proposed to be built in phases (phasing of development is recommended, <br /> and will be required for projects involving a developed area in excess of 25 acres), a <br /> phasing plan overlaid on the site plan, along with proposed start and completion dates of <br /> each phase, showing proposed phasing of buildings, of site infrastructure and of land <br /> clearing; <br /> 9. a I cus plan showing the site in relation to all major roadways and other significant <br /> landmarks-within one mile of the site; <br /> 10. detailed roadway, sidewalk, bikeway and parking area plans at a scale of 1 inch = 40 feet, <br /> with roadways shorn on plan and profile sheets as described in the Board's Rules and <br /> Regulations Goveming the Subdivision of Lard prepared by a registered civil engineer, in <br /> addition to typical roadway cross-sections; <br /> 11. detailed landscaping flans at a.scale of 1 inch = 20 feet; <br /> 12. plans and documents illustrating proposed utilities, including the proposed water supply <br /> system shoving proposed fire hydrant locations, and any proposed serer, electric, <br /> telephone, gas and cable television utilities, at a scale of 1 inch = 40 feet; <br /> 13. plans and documents illustrating the proposed system of wastewater collection, treatment <br /> and disposal, at an appropriate scale, along with documentation regarding the pro posed <br /> treatment technology, data d monstrating removal rates for , total nitrogen and <br /> phosphorous and a description of proposed owner hip, management and funding of the <br /> system; <br /> 14. plans and documents illustrating the proposed system of stormw ter collection, treatment. <br /> F <br /> and disposal, including manholes, catch basins, pipes, drainage ditches, roof drainage <br /> systems,,headwalls, surface-and subsurface discharge areas, retention ponds and any other- <br /> system elements, along with a stor grater management plan consistent ► it:h the provisions <br /> 1 <br />